duijianzhuwudefangleijiancezhong,shouxianyinggaijiancefangleizhuangzhidejieditiheyinxiaxiandeceshikou,bingqieyinggaizonghekaolvloudingceshidiandexuanquduijiancecanshudeyingxiang,haiyinggaigenjujianzhuwudedingduanshuaixianjinxingjiance,ruguoloudingshipingde,zaijinxingceshidianxuanzeshi,yinggaigenjuloudingmianjidejinxingxuanze2-4個測試點,如果檢測的建築物在兩層或兩層以上,需要在每一層選擇2個ge測ce試shi點dian,測ce試shi點dian通tong常chang選xuan擇ze在zai防fang雷lei網wang和he引yin下xia線xian的de連lian接jie位wei置zhi,在zai建jian築zhu物wu防fang雷lei檢jian測ce工gong作zuo對dui於yu有you引yin下xia線xian和he測ce試shi口kou的de建jian築zhu,應ying該gai通tong過guo引yin下xia線xian和he接jie線xian卡ka的de部bu位wei對dui接jie地di電dian阻zu進jin行xing測ce試shi,通tong過guo將jiang檢jian測ce的de數shu據ju與yu樓lou頂ding的de檢jian測ce數shu據ju進jin行xing對dui比bi,從cong而er可ke以yi檢jian測ce出chu建jian築zhu物wu防fang雷lei設she施shi是shi否fou可ke靠kao,特te別bie是shi樓lou層ceng和he引yin下xia線xian的de防fang雷lei網wang之zhi間jian的de連lian接jie是shi否fou連lian通tong且qie可ke靠kao。
一、打樁點的選擇
在(zai)現(xian)場(chang)防(fang)雷(lei)檢(jian)測(ce)工(gong)作(zuo)中(zhong),接(jie)地(di)樁(zhuang)的(de)位(wei)置(zhi)不(bu)同(tong),測(ce)量(liang)的(de)電(dian)阻(zu)值(zhi)也(ye)有(you)所(suo)不(bu)同(tong),在(zai)防(fang)雷(lei)檢(jian)測(ce)中(zhong)為(wei)了(le)保(bao)證(zheng)接(jie)地(di)電(dian)阻(zu)的(de)檢(jian)測(ce)的(de)可(ke)靠(kao)性(xing),在(zai)確(que)定(ding)打(da)樁(zhuang)點(dian)的(de)位(wei)置(zhi)時(shi),應(ying)該(gai)根(gen)據(ju)有(you)關(guan)的(de)要(yao)求(qiu)進(jin)行(xing)選(xuan)擇(ze),在(zai)距(ju)離(li)檢(jian)測(ce)點(dian)20m、40m分別打入兩個金屬樁,作為檢測的電流和電壓的輔助級,並且應該保證電壓輔助級、電流輔助級以及檢測點之間應該在同一條直線上,並且在進行選擇打樁點的過程中應該科學合理的進行電壓極點和電流極點的位置。
二、連接導線的使用
接(jie)地(di)電(dian)阻(zu)測(ce)試(shi)儀(yi)是(shi)防(fang)雷(lei)檢(jian)測(ce)中(zhong)重(zhong)要(yao)的(de)設(she)備(bei)之(zhi)一(yi),其(qi)工(gong)作(zuo)原(yuan)理(li)主(zhu)要(yao)是(shi)電(dian)流(liu)通(tong)過(guo)導(dao)線(xian)以(yi)及(ji)電(dian)流(liu)產(chan)生(sheng)電(dian)壓(ya),然(ran)後(hou)將(jiang)產(chan)生(sheng)的(de)電(dian)壓(ya)值(zhi)與(yu)基(ji)準(zhun)電(dian)壓(ya)進(jin)行(xing)比(bi)較(jiao),從(cong)而(er)推(tui)算(suan)出(chu)接(jie)地(di)電(dian)阻(zu)值(zhi)的(de)大(da)小(xiao),在(zai)檢(jian)測(ce)的(de)過(guo)程(cheng)中(zhong)如(ru)果(guo)導(dao)線(xian)呈(cheng)彎(wan)曲(qu)狀(zhuang),則(ze)會(hui)直(zhi)接(jie)影(ying)響(xiang)防(fang)雷(lei)檢(jian)測(ce)數(shu)據(ju),並(bing)且(qie)在(zai)現(xian)場(chang)防(fang)雷(lei)檢(jian)測(ce)中(zhong),經(jing)常(chang)會(hui)遇(yu)到(dao)由(you)於(yu)樓(lou)層(ceng)比(bi)較(jiao)高(gao)而(er)導(dao)線(xian)不(bu)夠(gou)的(de)問(wen)題(ti),因(yin)此(ci)在(zai)需(xu)要(yao)進(jin)行(xing)加(jia)接(jie)導(dao)線(xian),在(zai)連(lian)接(jie)的(de)過(guo)程(cheng)中(zhong),必(bi)須(xu)確(que)保(bao)導(dao)線(xian)連(lian)接(jie)的(de)緊(jin)密(mi)性(xing),在(zai)檢(jian)測(ce)數(shu)據(ju)確(que)定(ding)的(de)過(guo)程(cheng)中(zhong),應(ying)該(gai)把(ba)加(jia)接(jie)的(de)導(dao)線(xian)產(chan)生(sheng)電(dian)阻(zu)值(zhi)減(jian)去(qu),從(cong)而(er)保(bao)證(zheng)接(jie)地(di)電(dian)阻(zu)的(de)正(zheng)確(que)性(xing),如(ru)果(guo)想(xiang)要(yao)減(jian)去(qu)的(de)電(dian)阻(zu)值(zhi)具(ju)有(you)合(he)理(li)性(xing),還(hai)應(ying)該(gai)進(jin)行(xing)考(kao)慮(lv)打(da)樁(zhuang)距(ju)離(li)、季節問題以及導線的長度和導線的伸展程度等因素。
三、氧化層的處理
在防雷檢測工作中,為了保證檢測的可靠性,注意由於接地樁、檢jian測ce點dian以yi及ji線xian夾jia都dou屬shu於yu金jin屬shu物wu,長chang期qi在zai空kong氣qi中zhong,其qi表biao麵mian將jiang會hui被bei一yi氧yang化hua層ceng覆fu蓋gai,氧yang化hua層ceng具ju有you一yi定ding的de絕jue緣yuan性xing,如ru果guo不bu及ji時shi除chu去qu,將jiang會hui對dui檢jian測ce的de可ke靠kao性xing造zao成cheng嚴yan重zhong影ying響xiang,在zai進jin行xing防fang雷lei檢jian測ce前qian首shou先xian應ying將jiang接jie地di裝zhuang置zhi和he引yin下xia線xian的de檢jian測ce點dian處chu表biao麵mian的de氧yang化hua層ceng去qu除chu,為wei了le避bi免mian這zhe種zhong情qing況kuang的de發fa生sheng,接jie地di裝zhuang置zhi設she置zhi可ke以yi設she計ji不bu鏽xiu鋼gang材cai料liao,在zai防fang雷lei檢jian測ce的de過guo程cheng中zhong,除chu了le應ying該gai對dui檢jian測ce點dian進jin行xing打da磨mo處chu理li之zhi外wai,還hai應ying該gai在zai檢jian測ce點dian和he夾jia子zi處chu金jin屬shu表biao麵mian比bi較jiao亮liang的de凸tu起qi部bu分fen相xiang連lian接jie,從cong而er能neng夠gou提ti高gao檢jian測ce數shu據ju的de可ke信xin度du。